The content of the coding is lines, with and characters each, according to the example below. A: Production day A = Monday, B = Tuesday, C = Wednesday, , D=Thursday, etc. Penguin Fault Finding Video 2. The electronic unit is a dual voltage device.
V and 24V power supply systems. Resistance (Ohms) readings for compressor windings 1.
The cable from the controller connects to the compressor by means of a four-way plug that is a friction-fit onto four pins on the compressor, which are arranged in a diamond pattern. How much amperage does the DC compressor refrigerator typically consume running on volts DC? This category contains DC Compressor and controllers from both of these companies. The fault code will only be shown when the compressor fails to start or stops. Key features of this revolutionary compressor include rapid cooling, a low amp draw, and a whisper quiet operation.
They can be used for both refrigerators and freezers. Danfoss BD and 50F Fault Diagnostic. A simple valve plate allows gas to be drawn in on the down‐ stroke, and the gas to be compressed and then released on the up‐stroke.
The top supplying country is China (Mainland), which supply 1 of danfoss bd35f compressor respectively. Save danfoss bd35f to get e-mail alerts and updates on your eBay Feed. The compressors are intended especially for use in mobile applications, e. Productivity increases from 0compressors per week at the beginning of the year to 7per week at the end.
The excellent performance of the DC series safeguards foo medical and telecommunication. It will run the compressor on 12V or 24V DC when AC power is not available. Is there a freezer, if yes then evap fan should cut off when unit defrosts freezer section.
If no fan will always run when thermostat is calling for cooling. Yes, after running the ten minutes you would notice a difference in the temp of the discharge line, not in the conditioned area. Designed and manufactured by Secop for DANFOSS - DEHC.
The BD compressors must be mounted in a dry and clean place. Condensing temperatures: Max. C at stable conditions and max. Ambient temperatures: Min. Can be used as a replacement for a dead compressor on an old system, or can be used on a new system.
The datasheet for the BD35F can accessed by clicking the following link : BD35F Datasheet. Usually ships within days.
Answer: Servicing a DBwith a capillary tube expansion device is the same as servicing your old BD compressor except with 134a there is a small pressure difference. If you do need to add refrigerant follow the steps listed on page and to the letter and you will end up with an efficient system. The standard settings for 24V power supply systems appear from Fig. Other settings (Fig.
4) are optional if a connec tion which includes a resistor (9) is established between terminals C and P. I have intentionally, and fairly stalwartly, maintained ignorance about refrigeration systems. This compressor ’s Btu output capacity is small for that size refrigerator in a warm climate. In short, I turn on the power to the fridge Compressor Kicks in Seconds On - then goes off About minutes later Compressor kicks in Seconds on - then goes off And continues like this. The Control Module is an electronic device and is essential for running the compressor.
V for a 24V power supply system. It is considered a direct replacement. Simply remove a single screw to release module for the side of the compressor to reveal the 3-pin plug that attaches the module to the compressor. This part will also suit other brands of fridges eg.
Customers please note : Please check that the unit to be replaced resembles the unit pictured prior to ordering. If this fuse is blown there are two reasons why either power wires to module are reversed or module has an internal failure. You may have to register before you can post: click the register link above to proceed.
After some investigation decided the. The replacement unit is now the latest updated model and is completely black (as pictured above). Tailored for People in Motion. BD350GH compressors for V DC, R 134a HBP for telecommunication. All compressors are equipped with an electronic control unit with built in speed control, thermostat signal, thermal protection, safety against destructive battery discharge, electronic thermostat and fan speed control on selected models via PC software.
Also pict of the Wave form on one set of windings on a good compressor. The available instructions for light commercial and direct current compressors contain essential information for product installation and start-up. IT IS NOT DESIGNED FOR HOUSEHOLD USE. A Keel-cooled system is a step up from a water-cooled system because the condenser is outside of the vessel, instead of pumping water into the boat and then back over the side.
Instructions for light commercial compressors. DC refrigerator for marine applications. Features an LED interior light. Reversible, safe and stylish recessed doors. Can be flush- or proud-mounted without additional hardware.
Self-ventilated design for easier integration. This includes all DC-Only Isotherm Cruise Elegance series refrigerators and freezers. Has a potentiometer for adjusting the running speed of the compressor.
The unit has a switch for volt or volt operation and has a speed adjustment from 0to 5RPM.