FREE Shipping on eligible orders. ERZE valve an excellent replacement for all OEM BI and BBI valves as well as other applications requiring a R- 410A expansion valve such as I and RI valves. The ERZE valve utilizes the KT-element design for the higher pressures of R- 410A. This valve may also be applied in bi-directional applications. The thermostatic expansion valve ( TXV ) is a precision device, which is designed to regulate the rate at which liquid refrigerant flows into the evaporator.


This controlled flow is necessary to maximize the efficiency of the evaporator while preventing excess liquid refrigerant from returning to the compressor (floodback).

Lennox R- 410A Expansion Valve OEM 60M99. Scenario 2: Rvalve on a 410A system. The bulb charge is lower pressure than the Eq port pressure. This will close the valve starving the evaporator. If the valve has a larger port, the larger port may help to compensate here however the superheat will likely run high.


How to charge a 410A unit with a txv valve - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. Thermostatic Expansion Valves.


Select the TXV to correspond with the tonnage of your air conditioner or heat pump, as well as to match the type of refrigerant your systems uses, R-(standard) or R- 410A (new alternative).

An internally equalized valve should never be substituted for an externally equalized valve. The TXV determines which refrigerant can be used with a coil. Most new coils can be used with either Ror R410A providing that the correct TXV is used. With the TXV -3 you can be assured that your one-and-a-half to two-and-a-half ton system is getting the proper refrigerant flow, even through changing conditions.


Since this valve is installed externally, it is easy to service and maintain. To Ton TXV Kit - R- 410A Refrigerant $83. Add to Cart (Reviews) Compare. Probably the most common problem with the TXV is improper installation. This is a good reason why it is important to find or select a good HVAC contractor.


Can you install a 410a condensing unit on a rsystem - Duration:. How to recharge the AC with a TXV grayfurnaceman. A TXV Expansion Valve , 2. Unsubscribe from grayfurnaceman? Charging a System that is Very Low on Refrigerant, Avoid the Evap Freezing! Fill Your Cart With Color today!


HVAC supplies, parts and equipment. The Symptoms of a Restricted TXV How to identify when a liquid-line restriction is starving a system of refrigerant Figure 1: A healthy, happy, and unrestricted thermostatic expansion valve. Get the refrigeration TXV valves you need on LennoxPros.


Low prices and always free shipping.

Trane XBunit was freezing, repair guy said it was thermal expansion valve ( TXV ) and told me it wuld be $3for two techs two hours to come out and fix it. TXV Valve Bodies (9) Power Elements (28). The valve will assume a stable position when these forces are equalized.


Failures can also stem from improper installation, specifically the failure to properly use nitrogen when braising the system’s refrigerant lines. R- 410a systems operate at a much higher pressure than R-systems, and they have a much smaller orifice. Check Out R410a Txv on eBay. Wide Selection of Goodman HVAC Equipment.


The ER valve serves as a functional replacement. The expansion valve bulb must always be installed ahead of any liquid lock. Information courtesy Danfoss. A defective TXV that in a starved evaporator can be the result of a lost refrigerant charge within the sensing bulb of the valve. This is due to the fact that the refrigerant charge in its sensing bulb is the opening force of the TXV.


The TRvalves are available for R-and R- 410A systems. Air Conditioning TXV Kits, Type TR6. The aftermarket versions are delivered with internal check valve. With the TX5N you can be assured that your three-and-a-half to five ton system is getting the proper refrigerant flow, even through changing conditions.


It is designed for R- 410A refrigerant. Discover How To Repair Anything! DIY Supplies For Your Home or Garden Needs. The liquid injection depends on the refrigerant superheat at the evaporator outlet, where the bulb must be placed.


NOTE: This TXV kit is for R- 410A refrigerant and must always match the refrigerant type listed on the name plate of the outside unit. Kit Identification Confirm the TXV Kit type that is approved to be used with the coil or air handler. The TXV cannot be adjusted open or close it is a modulating valve.


Turning the adjustment stem clockwise will only increase spring pressure causing a higher superheat. Use wrench and backup wrench, to avoid damage to tubing or valve , to attach TXV to distributor.